Operate the Real Arm · xArm 6 · Step 3 of 9
Set Up the Arm
Setting up takes the arm, powered up and connected to Studio, to ready for the approved task: checked against its approved settings with lab staff, enabled, at a known starting position, with the part and the tool ready and the program chosen. Nothing moves until lab staff have confirmed the settings.
Check the Arm's Settings with Lab Staff

Before motion is enabled, lab staff confirm that the arm's speed, payload, workspace and safety configuration are the approved ones23. Read each item to them from Studio:
- State and Mode, in the status panel1.
- Mounting: it must match how the arm is really installed. A wrong setting stops the arm judging gravity, with frequent collision stops and uncontrolled motion in manual mode4. On 2026-10-16 it read floor mounting5.
- Payload and TCP, under Settings > Motion > TCP: they must match the tool actually fitted6. On 2026-10-16 the payload read 0.00 kg: check it with lab staff against the five-cup suction tool fitted before Manual Mode is used78.
- Safety, under Settings > Safety: the safety boundary, reduced mode and the speed limits are what lab staff approved910.
- Collision detection, on at the approved sensitivity11.
Warning
Enable the Arm
- When lab staff confirm the settings, click Enable in Studio. It turns the motors on, and the button disappears once the arm is enabled1314.
- From now on treat the arm as moving, even when it looks still: it may be waiting for a signal15.
Go to a Known Starting Position
- Set the Live Control speed slider low before any move. It runs from 1% (2.3 mm/s) to 100% (230 mm/s)16.
- Make sure the path is clear, then press and hold Initial Position. The arm moves to its initial position, by default every joint at 017.
Load the Part and Check the Tool
- Place the part where the approved program picks it up, as lab staff show you, with the arm still1819.
- The xArm 6's tool is a suction tool with five cups8. Before the run, test it on a part on the work surface with your hands clear: see Run18.
Select the Approved Program
- Choose only the existing program lab staff have approved. Do not edit it: creating or changing programs is the next step, not this one20.
- In Blockly, open that project. Run and Pause start and pause it21.
Make the Operating Area Safe