Operate the Real Arm · xArm 850 · Step 5 of 9
Monitor the Arm
While the arm works, you watch two things: what Studio says the arm is doing, and what the arm and the card are really doing. When the two disagree, or you are unsure, stop the arm.
The Status Panel

Studio shows the arm's status beside its picture of the arm2:
| Item | What it tells you | Normal for the approved task |
|---|---|---|
| State | Whether the arm is moving, ready, paused or stopped3456 | Moving during a move; Stop when it has stopped or after an error61 |
| Mode | The control mode. Position is the default after start-up72 | Position; Manual only while you guide the arm by hand81 |
| Payload | The tool's mass setting, in kg9 | The approved value. On 2026-10-22 it read 0.61 kg1 |
| Mounting | How the controller thinks the arm is installed10 | The approved value. On 2026-10-22 it read Floor1 |
| X, Y, Z, roll, pitch, yaw | Where the tool point is, in the base coordinate system211 | Changing while the arm moves, still when it stops23 |
| J1 to J6 | Each joint's angle2 | Inside each joint's limits: a joint past its limit raises error code C2312 |
- A change of a critical setting (mode, payload, TCP offset or collision sensitivity) puts the arm in a state where it accepts no commands until it is set to ready again13.
Inputs and Outputs

- Settings > Externals > Controller IO > IO State shows the control box's inputs and outputs14. The End Effector IO page shows the tool's inputs and outputs, updated five times a second15.
- With the arm stopped on 2026-10-22, every control box input read 1 and every output was off14.
- Look, do not click: clicking an output's button switches that output14.
What to Watch at the Arm
- The card stays flat on the suction cup while it is carried1617.
- Nobody enters the working area, and nothing is put in it18.
- An arm that looks stopped may be about to move. Treat it as moving19.
- Anything you did not expect, such as a move off the planned path or an error message: stop the arm and ask lab staff for help20.
When to Stop
- Click Studio's STOP for anything that is not normal. It stops the arm at once21.
- Press the emergency stop if anyone could be hurt2223.
- Then follow Abnormal conditions24.
Printed from https://www.anotherplace.com/learn/en/xarm-850/operate/monitor. Every line cites its source on that page.